Your current location: HomeProducts & ServicesPower MeterDS600 series intelligent motor protector

DS600 series intelligent motor protector

ProductOverview

The products are our new generation of intelligent motor protection controller. The product cooperates with contactor, soft starter, and moulded case circuit breaker to offer a set of specialized solution integrating control, protection, monitoring and bus communication for the LV AC motor circuit. It replace the thermal relay, thermal protector, leakage protector, under-voltage protector and other protection devices, and eliminates the time relay, intermediate relay, auxiliary relay, current transformer, instrumentation, control and selector switch, programmable logic controller, transmitter and other add-on components, thereby rendering an ideal option for intelligent MCC. The device is suitable for AC induction motors with AC 50Hz, rated voltage AC380V/660V, and rated current of below 800A.

Product Features

  • Satisfy the requirements in the latest national standard, Low Voltage Protector (JB/T10736-2007), and "tE time protection", and the requirements in the national standard, Explosive Atmospheres(GB3836.3-2000);
  • Integrate the protection, measurement, control, and communication functions in one;
  • Flexible protection configuration, input or exit, alarm or trip as required;
  • Small size, MNS 1/4 drawer cabinet can be easily accommodated;
  • High reliability, professional industrial modular design, the use of industrial-grade high-performance microprocessors;
  • Precise protection, direct sampling of three-phase AC current, and voltage, precise protection and control through reliable mathematical model;
  • All Chinese interface, easy maintenance;
  • Fault memory function, capable of recording 8 cycles of fault parameters.

Main technical parameters

Performance Parameters
Main circuit Rated working current (In) 2A, 6.3A, 25A, 63A, 100A (Built-in current transformer), 250A, 500A, 800A(External current transformer)
Rated working voltage (Ue) AC380/660V 50Hz
Rated insulation voltage (Ui) 690V
Insulation strength Power frequency withstand voltage 2KV, 50Hz, 1min; impact withstand voltage 5KV, 1.2/50Us
Measurement Accuracy Current 10% In ~120% In accuracy:±0.5%
120% In ~800% In accuracy:±1%
Grounding current 10% Ir1 ~100% Ir1 accuracy:±1%
Leakage current 10% Ir1 ~120% Ir1 accuracy:±1%
Voltage 20%Ue~120%Ue accuracy:±0.5%
Frequency 40Hz~65Hz accuracy:±0.05Hz
Power Factor -1~1 accuracy:±1%
Power 0~1000kW accuracy:±5%
Electric energy 0~65535kWh accuracy:±5%
Peripheral interface Output node 5DO, programmable function
Rated load capacity: resistive load AC250V/6A; DC30V/6A, inductive load AC250V/2A; DC30V/2A
Switchs input 8DI, programmable function, built-in 24V power supply, optocoupler isolation
Analog output 1 way 4 ~ 20mA signal output (optional)
Auxiliary power Rated working voltage AC 85V-265V/DC 100V-280V
Power consumption 7VA/7W
Communication RS485 interface Asynchronous half duplex, N, 8, 1, isolation
Baud rate 1200bps ~38400bps
Communication protocol MODBUS-RTU
Function Read and write settings parameters, read measurement real-time values
Applicable environment Protection class IP30
Installation classification III
Altitude no higher than 2000m
Operating temperature -20℃ ~ 60℃
Storage Temperature -40℃ ~ 85℃
Relative humidity 5% ~95% non-condensing